@ -79,6 +79,8 @@ class AX25KISSInterface(Interface):
|
||||
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 564
|
||||
|
||||
self.pyserial = serial
|
||||
self.serial = None
|
||||
@ -304,7 +306,7 @@ class AX25KISSInterface(Interface):
|
||||
in_frame = True
|
||||
command = KISS.CMD_UNKNOWN
|
||||
data_buffer = b""
|
||||
elif (in_frame and len(data_buffer) < RNS.Reticulum.MTU+AX25.HEADER_SIZE):
|
||||
elif (in_frame and len(data_buffer) < self.HW_MTU+AX25.HEADER_SIZE):
|
||||
if (len(data_buffer) == 0 and command == KISS.CMD_UNKNOWN):
|
||||
# We only support one HDLC port for now, so
|
||||
# strip off the port nibble
|
||||
|
@ -60,6 +60,9 @@ class AutoInterface(Interface):
|
||||
self.netifaces = netifaces
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 1064
|
||||
|
||||
self.IN = True
|
||||
self.OUT = False
|
||||
self.name = name
|
||||
|
@ -306,6 +306,8 @@ class I2PInterfacePeer(Interface):
|
||||
def __init__(self, parent_interface, owner, name, target_i2p_dest=None, connected_socket=None, max_reconnect_tries=None):
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 1064
|
||||
|
||||
self.IN = True
|
||||
self.OUT = False
|
||||
@ -569,7 +571,7 @@ class I2PInterfacePeer(Interface):
|
||||
in_frame = True
|
||||
command = KISS.CMD_UNKNOWN
|
||||
data_buffer = b""
|
||||
elif (in_frame and len(data_buffer) < RNS.Reticulum.MTU):
|
||||
elif (in_frame and len(data_buffer) < self.HW_MTU):
|
||||
if (len(data_buffer) == 0 and command == KISS.CMD_UNKNOWN):
|
||||
# We only support one HDLC port for now, so
|
||||
# strip off the port nibble
|
||||
@ -595,7 +597,7 @@ class I2PInterfacePeer(Interface):
|
||||
elif (byte == HDLC.FLAG):
|
||||
in_frame = True
|
||||
data_buffer = b""
|
||||
elif (in_frame and len(data_buffer) < RNS.Reticulum.MTU):
|
||||
elif (in_frame and len(data_buffer) < self.HW_MTU):
|
||||
if (byte == HDLC.ESC):
|
||||
escape = True
|
||||
else:
|
||||
@ -660,6 +662,9 @@ class I2PInterface(Interface):
|
||||
def __init__(self, owner, name, rns_storagepath, peers, connectable = False):
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 1064
|
||||
|
||||
self.online = False
|
||||
self.clients = 0
|
||||
self.owner = owner
|
||||
@ -757,6 +762,7 @@ class I2PInterface(Interface):
|
||||
spawned_interface.announce_rate_grace = self.announce_rate_grace
|
||||
spawned_interface.announce_rate_penalty = self.announce_rate_penalty
|
||||
spawned_interface.mode = self.mode
|
||||
spawned_interface.HW_MTU = self.HW_MTU
|
||||
RNS.log("Spawned new I2PInterface Peer: "+str(spawned_interface), RNS.LOG_VERBOSE)
|
||||
RNS.Transport.interfaces.append(spawned_interface)
|
||||
self.clients += 1
|
||||
|
@ -73,6 +73,8 @@ class KISSInterface(Interface):
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 564
|
||||
|
||||
if beacon_data == None:
|
||||
beacon_data = ""
|
||||
|
||||
@ -279,7 +281,7 @@ class KISSInterface(Interface):
|
||||
in_frame = True
|
||||
command = KISS.CMD_UNKNOWN
|
||||
data_buffer = b""
|
||||
elif (in_frame and len(data_buffer) < RNS.Reticulum.MTU):
|
||||
elif (in_frame and len(data_buffer) < self.HW_MTU):
|
||||
if (len(data_buffer) == 0 and command == KISS.CMD_UNKNOWN):
|
||||
# We only support one HDLC port for now, so
|
||||
# strip off the port nibble
|
||||
|
@ -49,6 +49,9 @@ class LocalClientInterface(Interface):
|
||||
def __init__(self, owner, name, target_port = None, connected_socket=None):
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 1064
|
||||
|
||||
self.online = False
|
||||
|
||||
self.IN = True
|
||||
@ -177,7 +180,7 @@ class LocalClientInterface(Interface):
|
||||
elif (byte == HDLC.FLAG):
|
||||
in_frame = True
|
||||
data_buffer = b""
|
||||
elif (in_frame and len(data_buffer) < RNS.Reticulum.MTU):
|
||||
elif (in_frame and len(data_buffer) < self.HW_MTU):
|
||||
if (byte == HDLC.ESC):
|
||||
escape = True
|
||||
else:
|
||||
|
@ -56,6 +56,8 @@ class PipeInterface(Interface):
|
||||
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 1064
|
||||
|
||||
self.owner = owner
|
||||
self.name = name
|
||||
@ -137,7 +139,7 @@ class PipeInterface(Interface):
|
||||
elif (byte == HDLC.FLAG):
|
||||
in_frame = True
|
||||
data_buffer = b""
|
||||
elif (in_frame and len(data_buffer) < RNS.Reticulum.MTU):
|
||||
elif (in_frame and len(data_buffer) < self.HW_MTU):
|
||||
if (byte == HDLC.ESC):
|
||||
escape = True
|
||||
else:
|
||||
|
@ -111,6 +111,8 @@ class RNodeInterface(Interface):
|
||||
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 508
|
||||
|
||||
self.pyserial = serial
|
||||
self.serial = None
|
||||
@ -439,7 +441,7 @@ class RNodeInterface(Interface):
|
||||
command = KISS.CMD_UNKNOWN
|
||||
data_buffer = b""
|
||||
command_buffer = b""
|
||||
elif (in_frame and len(data_buffer) < RNS.Reticulum.MTU):
|
||||
elif (in_frame and len(data_buffer) < self.HW_MTU):
|
||||
if (len(data_buffer) == 0 and command == KISS.CMD_UNKNOWN):
|
||||
command = byte
|
||||
elif (command == KISS.CMD_DATA):
|
||||
|
@ -62,6 +62,8 @@ class SerialInterface(Interface):
|
||||
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 564
|
||||
|
||||
self.pyserial = serial
|
||||
self.serial = None
|
||||
@ -152,7 +154,7 @@ class SerialInterface(Interface):
|
||||
elif (byte == HDLC.FLAG):
|
||||
in_frame = True
|
||||
data_buffer = b""
|
||||
elif (in_frame and len(data_buffer) < RNS.Reticulum.MTU):
|
||||
elif (in_frame and len(data_buffer) < self.HW_MTU):
|
||||
if (byte == HDLC.ESC):
|
||||
escape = True
|
||||
else:
|
||||
|
@ -79,6 +79,8 @@ class TCPClientInterface(Interface):
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 1064
|
||||
|
||||
self.IN = True
|
||||
self.OUT = False
|
||||
self.socket = None
|
||||
@ -293,7 +295,7 @@ class TCPClientInterface(Interface):
|
||||
in_frame = True
|
||||
command = KISS.CMD_UNKNOWN
|
||||
data_buffer = b""
|
||||
elif (in_frame and len(data_buffer) < RNS.Reticulum.MTU):
|
||||
elif (in_frame and len(data_buffer) < self.HW_MTU):
|
||||
if (len(data_buffer) == 0 and command == KISS.CMD_UNKNOWN):
|
||||
# We only support one HDLC port for now, so
|
||||
# strip off the port nibble
|
||||
@ -319,7 +321,7 @@ class TCPClientInterface(Interface):
|
||||
elif (byte == HDLC.FLAG):
|
||||
in_frame = True
|
||||
data_buffer = b""
|
||||
elif (in_frame and len(data_buffer) < RNS.Reticulum.MTU):
|
||||
elif (in_frame and len(data_buffer) < self.HW_MTU):
|
||||
if (byte == HDLC.ESC):
|
||||
escape = True
|
||||
else:
|
||||
@ -405,6 +407,9 @@ class TCPServerInterface(Interface):
|
||||
def __init__(self, owner, name, device=None, bindip=None, bindport=None, i2p_tunneled=False):
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 1064
|
||||
|
||||
self.online = False
|
||||
self.clients = 0
|
||||
|
||||
@ -460,6 +465,7 @@ class TCPServerInterface(Interface):
|
||||
spawned_interface.announce_rate_grace = self.announce_rate_grace
|
||||
spawned_interface.announce_rate_penalty = self.announce_rate_penalty
|
||||
spawned_interface.mode = self.mode
|
||||
spawned_interface.HW_MTU = self.HW_MTU
|
||||
spawned_interface.online = True
|
||||
RNS.log("Spawned new TCPClient Interface: "+str(spawned_interface), RNS.LOG_VERBOSE)
|
||||
RNS.Transport.interfaces.append(spawned_interface)
|
||||
|
@ -57,6 +57,9 @@ class UDPInterface(Interface):
|
||||
def __init__(self, owner, name, device=None, bindip=None, bindport=None, forwardip=None, forwardport=None):
|
||||
self.rxb = 0
|
||||
self.txb = 0
|
||||
|
||||
self.HW_MTU = 1064
|
||||
|
||||
self.IN = True
|
||||
self.OUT = False
|
||||
self.name = name
|
||||
|